Is your AWS Foundational Technical Review (FTR) being held back by security misconfigurations, incomplete compliance evidence, or infrastructure issues your engineering team hasn't resolved?
For SaaS providers and Independent Software Vendors (ISVs), these technical gaps can delay AWS partner validation and divert developers from building core product features. The risks are significant:
Verizon's 2026 Data Breach Investigations Report found that 31% of breaches began with vulnerability exploitation (Source).
Orca Security's 2025 State of Cloud Security Report found that 17% of organizations had at least one Infrastructure-as-Code artifact that configured an Amazon S3 bucket to grant public GET (read) access (Source).
These findings highlight why identifying and correcting cloud security weaknesses matters.
This guide explains how to pass AWS FTR in 2026 by verifying submission readiness, preparing acceptable evidence, resolving infrastructure gaps, and addressing validation failures.
How to Check Your AWS FTR Readiness Before Applying
Before requesting AWS Foundational Technical Review (FTR) validation, check your software solution's eligibility in AWS Partner Central. Incomplete prerequisites can block submission even when your AWS infrastructure is technically ready.
Verify the Six AWS Partner Central Prerequisites
Sign in to AWS Partner Central, navigate to Build โ Solutions, select your software solution, and open the Validation tab.
Use the following checklist to identify incomplete prerequisites and determine the necessary corrective action.
Prerequisite | How to Verify | Corrective Action |
Marketplace product association | Check whether the intended AWS Marketplace product is linked to your solution. | Link the correct product after verifying the AWS account association. |
Single product association | Confirm that only one Marketplace product is linked. | Remove additional products or create separate solutions as appropriate. |
No non- Marketplace products | Check that the solution does not contain products that are not listed on AWS Marketplace. | Remove non-Marketplace products from the solution. |
Eligible software type | Confirm the product is SaaS, AMI, Container, or Machine Learning software. | Associate an eligible software product. |
Approved AWS hosted architecture | Check the product's architecture approval status. | Upload or correct the architecture diagram showing that the solution runs on AWS infrastructure through the AWS Marketplace Management Portal and complete approval. |
AWS Revenue Measurement | Verify onboarding in the attributed revenue dashboard. | Enable AWS Revenue Measurement and confirm that reporting data is available. |
AWS evaluates these checks sequentially; later checks remain blocked until earlier checks pass.
Resolve Incomplete Prerequisites and Confirm Readiness
Two practical details can prevent unnecessary troubleshooting:
Architecture approval: Uploading an architecture diagram is not the same as obtaining approval. Confirm that AWS has approved the architecture before proceeding.
AWS Revenue Measurement reporting delay: AWS states that measurement data can take up to seven days to appear after enabling AWS Revenue Measurement. Verify onboarding and reporting status before treating the delay as a technical failure.
After correcting a prerequisite, return to the Validation tab and select Refresh to update its status.
Proceed with FTR report submission once all six prerequisites display Complete.
Source: AWS Partner Central - Requesting FTR
How to Prepare FTR Evidence That Passes AWS Validation
Before submitting your AWS Foundational Technical Review (FTR), inspect your selected validation report for missing information, outdated evidence, or inconsistencies that could lead to an Action Required result.
Check Your SOC 2 Type II Report for Submission Errors
If your organization already has a SOC 2 Type II audit report, verify that the actual document meets AWS's acceptance criteria.
Validation Check | What to Verify |
Report freshness | Confirm the report was issued within the past year. |
Auditor opinion | Verify that the independent auditor issued an unqualified opinion. |
AWS infrastructure scope | Check that the system description explicitly includes the AWS-hosted components supporting your solution. |
Solution identification | Ensure the software solution submitted for FTR is covered by the audit. |
Trust services criteria | Confirm that the report covers both Security and Availability criteria. |
For example, if your SaaS product runs on Amazon ECS and Amazon RDS, verify that the audited system description includes the AWS-hosted components supporting that solution.
If essential audit information is missing, consult your auditor about the appropriate corrective documentation rather than modifying the independent audit report yourself.
Check Your WAFR Report for Missing Evidence and High-Risk Issues
For WAFR-based validation, open the relevant workload in the AWS Well-Architected Tool and verify the following before generating the report.
Validation Check | What to Verify |
Report freshness | The WAFR report must be less than one year old. |
Workload identification | The specific software solution appears in the workload name or description. |
Reviewer information | The reviewer owner field includes the reviewer's full name and email address. |
Security | Zero high-risk issues (HRIs) remain. |
Reliability | Zero HRIs remain. |
Operational Excellence | Zero HRIs remain. |
Assessment source | The report was generated from a review conducted using the AWS Well-Architected Tool. |
If any mandatory information is missing, update the workload assessment or resolve the relevant findings before exporting the report.
Run a Final FTR Evidence Quality Check Before Uploading
Once the report-specific checks are complete, perform three final submission checks:
Confirm document consistency: Ensure the final PDF corresponds to the software solution selected in AWS Partner Central.
Review the exported PDF: Check that the document is complete, readable, and reflects the latest approved audit or workload assessment.
Verify upload requirements: Ensure the PDF does not exceed AWS's 3 MB file-size limit.
These checks help reduce avoidable document-related validation errors before submitting your FTR request.
Source: AWS Partner Central - Request Foundational Technical Review.
How to Identify and Fix Technical Gaps Before AWS FTR
For AWS Foundational Technical Review (FTR) preparation, engineering teams should examine the configurations supporting their software solution and verify that critical security, reliability, and operational controls work as intended. This is particularly important when preparing a WAFR report for FTR validation.
Audit IAM Access, Encryption, and CloudTrail Configurations
Use AWS security and monitoring services to identify configuration weaknesses before generating your validation evidence.
Technical Check | How to Identify Gaps | How to Verify Remediation |
IAM least-privilege access | Use AWS IAM Access Analyzer to identify unintended external access and unused permissions. | Confirm unnecessary permissions have been removed and relevant findings are resolved. |
MFA and privileged identities | Review root-user and privileged-user MFA settings, long-term credentials, and access-key usage. | Verify MFA configuration and confirm unnecessary credentials are disabled or removed. |
Amazon S3 security | Inspect S3 Block Public Access settings, bucket policies, and default encryption. | Confirm intended access restrictions and encryption controls are effective. |
Amazon EBS and RDS protection | Review encryption and access configurations for storage volumes and databases. | Verify that applicable resources use approved encryption and access controls. |
AWS CloudTrail logging | Check active trails, AWS Region coverage, event selectors, and log destinations. | Confirm that required events are delivered and retained in the intended destination. |
Get insights in your inbox!!
Weekly tips on building smarter apps. Join 8,200+ founders and builders.
No spam. Unsubscribe anytime. We respect your privacy.
These checks align with AWS security best practices and help teams validate whether the underlying infrastructure meets the expectations documented in their architecture assessment.
Test Backup Recovery, Monitoring, and Incident Response
Security configuration alone does not demonstrate that an application can recover from outages or operate reliably.
Verify the following operational capabilities:
Backup recovery: Review AWS Backup coverage, backup-job results, retention policies, and restore-testing outcomes.
Recovery objectives: Establish measurable Recovery Point Objectives (RPOs) and Recovery Time Objectives (RTOs), then compare recovery-test results against those targets.
Application availability: Verify applicable Multi-AZ deployment, health checks, failover configurations, and dependency recovery mechanisms.
Monitoring and alerting: Confirm Amazon CloudWatch alarms cover critical workload indicators and notify responsible teams.
Incident response: Test escalation procedures, recovery runbooks, and incident responsibilities through controlled exercises.
For example, a successful Amazon RDS backup does not guarantee that an application can recover within its required RTO. Teams should test restoration, validate recovered data, and measure the complete recovery process.
Implement and Validate Infrastructure Fixes With Terraform and IaC
When findings affect multiple AWS resources, Infrastructure as Code (IaC) tools such as Terraform, AWS CloudFormation, and AWS CDK help engineers implement consistent, version-controlled corrections.
A practical remediation workflow involves four steps:
Map findings to infrastructure resources: Identify the affected AWS account, Region, resources, and corresponding infrastructure definitions.
Update and validate infrastructure code: Modify the relevant Terraform or IaC configuration, inspect the proposed changes, and perform security and policy checks.
Deploy approved changes: Use pull requests, peer reviews, and controlled CI/CD pipelines to manage infrastructure updates.
Verify the deployed fix: Confirm that the intended configuration is active and update the relevant architectural assessment when appropriate.
Important: A successful Terraform deployment does not automatically resolve a WAFR finding or guarantee FTR approval. Teams must independently verify that the deployed changes address the identified architectural risk.
These practices align with AWS guidance on infrastructure automation, security validation, and the Well-Architected improvement process.
How to Submit AWS FTR Without Avoidable Validation Errors
Once you complete your prerequisites, compliance evidence, and technical readiness checks, you can submit your AWS Foundational Technical Review (FTR) request through AWS Partner Central.
Before submitting, perform a final quality check to prevent administrative mistakes, incorrect document uploads, or inconsistencies between your software solution and validation evidence.
Final AWS FTR Pre-Submission Checklist
Final Check | What to Confirm |
Solution selection | You have selected the correct AWS Marketplace-linked software solution in Partner Central. |
Prerequisite status | Every prerequisite displays Complete in the Validation tab. |
Evidence consistency | The uploaded report corresponds to the software solution being validated. |
Document version | You're submitting the final report rather than an outdated draft or earlier assessment. |
PDF requirements | The report is readable, in PDF format, and does not exceed 3 MB. |
Submission permissions | Your Partner Central account has the necessary access to request validation. |
Submit Your AWS FTR Request in Partner Central
After completing the checklist:
Step 1
Sign in to AWS Partner Central and navigate to Build โ Solutions.
Step 2
Select the applicable software solution and open its Validation tab.
Step 3
Select Request validation and choose the appropriate report type.
Step 4
Upload the verified PDF and select Request FTR.
AWS automatically evaluates the submitted evidence and returns an Approved or Action required result within minutes.
An Approved status confirms successful FTR validation and displays the approval expiration date. An Action required status indicates that one or more document validation checks were unsuccessful.
For the official interface instructions, refer to AWS Partner Central - Request Foundational Technical Review.
Important: Automated validation can be completed within minutes, but it does not guarantee approval. The outcome depends on whether the selected solution satisfies AWS prerequisites and the submitted report meets the applicable acceptance criteria.
AWS FTR Validation Failed? How to Diagnose and Fix the Problem
An Action Required status in AWS Partner Central indicates that your Foundational Technical Review (FTR) submission failed one or more document validation checks. Review the feedback in your solution's Validation tab to identify the specific issue before correcting the evidence.
Identify Why AWS Returned an Action Required Status
Use the following troubleshooting matrix to match common validation problems with their likely causes and corrective actions.
Validation Issue | Possible Cause | Recommended Corrective Action |
Outdated report | The submitted SOC 2 Type II or WAFR report falls outside AWS's required validity period. | Obtain an updated qualifying report. |
Unacceptable SOC 2 opinion | The audit report does not contain an unqualified auditor opinion. | Consult the independent auditor regarding acceptable updated audit evidence. |
Incorrect solution scope | The report does not adequately identify the AWS-hosted software solution being validated. | Obtain corrected documentation through the appropriate audit or assessment process. |
Missing SOC 2 criteria | Security and Availability trust services criteria are not both included. | Coordinate with the auditor to establish acceptable coverage. |
Unresolved WAFR high-risk issues | The assessment identifies HRIs in Security, Reliability, or Operational Excellence. | Remediate the applicable findings, verify the results, and regenerate the report. |
Missing WAFR reviewer details | The reviewer owner field does not include the reviewer's full name and email address. | Update the workload metadata in AWS Well-Architected Tool and regenerate the report. |
Note: Incomplete AWS Marketplace, architecture approval, or AWS Revenue Measurement prerequisites generally prevent FTR submission. They should be resolved before troubleshooting post-submission report validation failures.
Fix Report Errors and Resubmit for Validation
After resolving the issue identified in AWS's feedback:
Prepare corrected evidence: Obtain or generate an updated report that addresses the failed validation check.
Resubmit the report: Return to the Validation tab in AWS Partner Central, select Resubmit, and upload the corrected PDF.
Check the new result: Review the updated approval status or any additional validation feedback.
AWS permits resubmission as many times as needed. Each submission is reviewed automatically and returns results within minutes.
For official requirements and resubmission instructions, see AWS Partner Central - Request Foundational Technical Review.
How to Maintain AWS FTR Readiness After Approval
Passing the AWS Foundational Technical Review (FTR) is an important milestone, but maintaining technical readiness requires ongoing attention as your software and cloud infrastructure evolve.
AWS FTR approval includes an expiration date displayed in AWS Partner Central. SaaS providers and Independent Software Vendors (ISVs) should keep architecture documentation accurate, monitor infrastructure changes, and prepare updated validation evidence before the expiration date.
To maintain FTR readiness:
Keep architecture documentation current: Update diagrams and technical records when introducing new AWS services, changing application dependencies, or modifying deployment architectures.
Monitor configuration drift: Use AWS Config, infrastructure monitoring, and version-controlled configurations to detect changes that may introduce security or operational risks.
Maintain compliance evidence: Coordinate with auditors and workload owners to ensure SOC 2 documentation or Well-Architected assessments reflect the software's current architecture.
Review architectural changes: Include security, reliability, and operational checks in development and release workflows, particularly after significant infrastructure updates.
Plan for FTR renewal: Track the approval expiration date in AWS Partner Central and begin preparing updated qualifying evidence before it expires.
For organizations using the AWS Well-Architected Tool, consider saving milestones after improvements to preserve a record of workload architecture and risk-reduction progress.
Maintaining these practices helps engineering teams manage architectural changes and avoid rebuilding their technical evidence from scratch when preparing for future FTR validation.
Conclusion
Passing AWS Foundational Technical Review (FTR) in 2026 requires more than submitting a compliance report. SaaS providers and Independent Software Vendors (ISVs) must verify AWS Partner Central eligibility, prepare qualifying validation evidence, and resolve technical gaps that could affect their readiness.
A structured approach to infrastructure assessment, security remediation, and evidence verification helps minimize avoidable validation errors and streamline the approval process. By maintaining accurate documentation, implementing reliable AWS architecture practices, and monitoring infrastructure changes, organizations can strengthen their technical readiness and prepare for future FTR renewals.
FAQs
Why are my AWS FTR prerequisites still incomplete?
AWS Partner Central checks FTR prerequisites sequentially. An incomplete earlier check can block subsequent checks. Review the Validation tab, resolve the first failed prerequisite, and select Refresh to update its status.
What if AWS Revenue Measurement data is missing?
After enabling AWS Revenue Measurement, data may take up to seven days to appear. Verify that your Marketplace product is onboarded in the attributed revenue dashboard, then refresh its prerequisite status in Partner Central.
Why was my SOC 2 Type II report rejected?
AWS may reject a SOC 2 Type II report if it is outdated, lacks an unqualified auditor opinion, excludes the AWS-hosted solution, or omits the Security and Availability trust services criteria. Review the validation feedback to identify the issue.
Can I resubmit AWS FTR after an Action required result?
Yes. AWS permits FTR resubmission as many times as needed. Review the failed checks in Partner Central, correct the report, and select Resubmit. Each submission is reviewed automatically and returns results within minutes.
How do I verify that a remediated WAFR finding is resolved?
Verify the deployed configuration, repeat relevant security or recovery checks, and update the workload assessment in AWS Well-Architected Tool. Confirm that the applicable high-risk finding no longer appears before generating an updated FTR report.
Written by
Paul Dhaliwal
Founder & Chief Executive Officer
Paul Dhaliwal is a tech innovator and Founder of CodeConductor, an open-source no/low-code platform. With 10+ years of experience in AI and scalable development, Paul focuses on crafting intelligent solutions that drive real-world value. A firm believer in the mantra "Eat, Sleep, Code, Repeat," he balances his passion for software with a love for travel and family.